Muonic X-ray energies and intensities (XR)
Muonic X-rays are emitted during transitions between atomic energy levels in a muonic atom. They are used for measurements of nuclear charge radii and for non-destructive elemental analysis.
Formation of muonic atoms
When a negative muon stops in matter, it is captured into a highly excited atomic orbit, forming a muonic atom. The muon subsequently undergoes transitions to lower energy levels through the emission of Auger electrons and muonic X-rays, eventually reaching the ground \(1s\) state.
X-ray energies and nuclear charge radii
The muon has the same electric charge as the electron but a mass approximately 207 times larger. Consequently, its atomic orbits are much smaller than the corresponding electronic orbits. This makes low-lying muonic states particularly sensitive to the finite size and charge distribution of the nucleus.
For a point-like nucleus, the Bohr radius of a muonic atom in the non-relativistic limit is given by
where \(\mu\) is the reduced mass of the muon–nucleus system, \(Z\) is the nuclear charge, and \(\alpha\) is the fine-structure constant. The numerical approximation assumes that the nuclear mass is much larger than the muon mass, so that \(\mu \simeq m_\mu\). The characteristic orbital radius scales inversely with the reduced mass and nuclear charge.
In a muonic atom, the muon wave function is spatially localized near the nucleus and can overlap significantly with the nuclear charge distribution. When this overlap is substantial, the point-charge approximation is inadequate, and the finite size of the nuclear charge distribution must be taken into account in the calculation of atomic energy levels. Muonic X-ray energies thus provide a sensitive probe of nuclear size and have long been used to determine nuclear charge radii. K-series muonic X-ray energies are therefore available as part of nuclear charge-radius compilations [1], [2].
Calculation of energies and intensities
Muonic atomic energy levels can be calculated by solving the Dirac equation with a potential derived from a finite nuclear charge distribution. Accurate calculations also require corrections such as vacuum polarization and electronic screening. The open-source code MuDIRAC provides calculations of muonic atomic levels, transition energies, and radiative transition probabilities [3].
Predicting the observed X-ray intensities is more difficult than calculating transition energies. The intensity of a spectral line depends on how atomic levels are populated and depopulated throughout the cascade, rather than on an individual radiative transition probability alone. Cascade calculations, such as the program developed by Akylas and Vogel, provide a framework for treating these processes [4].
However, the cascade and resulting line intensities can also depend on the chemical environment, material density, and physical state of the target. A calculation based on a simplified cascade model does not necessarily reproduce the intensities under all experimental conditions. Experimental measurements therefore remain essential for establishing reliable X-ray intensity data. Chemical effects on muonic X-ray intensities and density-dependent X-ray yields have been observed experimentally.
Experimental data and recent studies
Muonic X-ray spectra measured at PSI for a wide range of elements are available through the Mesoroentgen Spectra Catalogue. The catalogue provides a useful experimental reference for identifying spectral lines and comparing spectra across different elements.
More recently, Saito et al. measured muonic X-ray transition energies for five stable palladium isotopes, \(^{104,105,106,108,110}\mathrm{Pd}\), at the MuSIC-M1 beamline at RCNP, Osaka University. The measurements were used to deduce nuclear charge radii and investigate charge distributions, demonstrating the importance of the \(3d\text{–}2p\) transitions for determining both quantities [5].
Mizuno et al. developed a photon detection system covering a wide energy range for muonic X-ray spectroscopy. The system combines high-purity germanium detectors, BGO Compton suppressors, and digital data acquisition. Using this system, Mizuno et al. measured muonic X-ray energies and intensities for Au, Pb, and Bi, providing reference data for in-situ calibration of both the energy scale and detection efficiency [6]. The system will be used as the standard X-ray measurement system at the RCNP MuSIC facility.
Application to non-destructive elemental analysis
Muonic X-ray energies are characteristic of the emitting element and can therefore be used to identify the elemental composition of a sample. Their high energies allow X-rays emitted inside the sample to reach external detectors, enabling non-destructive analysis of bulk materials, including light elements. These capabilities support applications to archaeological objects, meteorites, and battery materials.
Muonic X-ray elemental analysis is being developed and used at facilities worldwide, including PSI in Switzerland, J-PARC MUSE and RCNP MuSIC [8] in Japan, and the RIKEN-RAL facility at ISIS in the United Kingdom [7].
References
- G. Fricke et al., Nuclear Ground State Charge Radii from Electromagnetic Interactions, At. Data Nucl. Data Tables 60, 177–285 (1995). DOI:10.1006/adnd.1995.1007.
- I. Angeli and K. P. Marinova, Table of experimental nuclear ground state charge radii: An update, At. Data Nucl. Data Tables 99, 69–95 (2013). DOI:10.1016/j.adt.2011.12.006.
- S. Sturniolo and A. Hillier, Mudirac: A Dirac equation solver for elemental analysis with muonic X-rays, X-Ray Spectrom. 50, 180–196 (2021). DOI:10.1002/xrs.3212.
- V. R. Akylas and P. Vogel, Muonic atom cascade program, Comput. Phys. Commun. 15, 291–302 (1978). DOI:10.1016/0010-4655(78)90099-1.
- T. Y. Saito et al., Muonic x-ray measurement for the nuclear charge distribution: The case of stable palladium isotopes, Phys. Rev. C 111, 034313 (2025). DOI:10.1103/PhysRevC.111.034313.
- R. Mizuno et al., Development of wide range photon detection system for muonic X-ray spectroscopy, Nucl. Instrum. Methods A 1060, 169029 (2024). DOI:10.1016/j.nima.2023.169029.
- A. Hillier et al., Element Specific Imaging Using Muonic X-rays, JPS Conf. Proc. 21, 011042 (2018). DOI:10.7566/JPSCP.21.011042.
- K. Ninomiya et al., Non-Destructive Elemental Analysis Using Negative Muon Obtained from DC Muon Beam Source; RCNP-MuSIC, RADIOISOTOPES 69, 13–17 (2020). DOI:10.3769/radioisotopes.69.13.